stake¹ÙÍø

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·£¬£¬£¬£¬£¬£¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¬Ã¦ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
RG-S5000-24GT4SFP-P
RG-S5000-24GT4SFP-P
RG-S5000-24GT4SFP-P
RG-S5000-24GT4SFP-P
RG-S5000-24GT4SFP-P
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

24¿ÚǧÕ×Èý²ãºÐʽ½ÓÈë²ãPoE½»Á÷»ú£¬£¬£¬£¬£¬£¬Ç§Õ×ÉÏÐУ¬£¬£¬£¬£¬£¬RG-S5000-24GT4SFP-P

ÎªÔ°ÇøÍøÂç½ÓÈë×°±¸ÌṩǧÕ×µ½×ÀÃæµÄÓ¦Ó㬣¬£¬£¬£¬£¬Í¬Ê±Ìṩ´óÈÝÁ¿µÄǧÕ×ÉÏÐдø¿í£¬£¬£¬£¬£¬£¬Öª×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔöÌíµÄÐèÒª

²úÆ·ÌØÕ÷£º

  • 24¸ö10/100/1000Base-TÒÔÌ«Íø¿Ú£¬£¬£¬£¬£¬£¬Ö§³ÖPoE+
  • 4¸ö×ÔÁ¦Ç§Õ×SFP¹â¿Ú
  • Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ£¬£¬£¬£¬£¬£¬¼ò»¯ÍøÂç¹ÜÀí
  • Ö§³ÖCPP/NFPP/RLDP/DHCP snooping¶àÖØÇå¾²·À»¤Õ½ÂÔ
  • ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬£¬ÖÇÄܵ÷ËÙ£¬£¬£¬£¬£¬£¬µÍÔëÇÒ½ÚÄÜ
Á¬Ã¦×Éѯ

²úÆ·¸ÅÊö

RG-S5000ϵÁн»Á÷»úÊÇstake¹ÙÍøÍøÂçÃæÏòÖÐÐ¡Ô°ÇøÍÆ³öµÄǧÕ×ÒÔÌ«Íø½»Á÷»ú¡£¡£ ¡£¡£¡£¡£¡£¡£¸ÃϵÁвúÆ·½ÓÄÉȫеÄÓ²¼þ¼Ü¹¹Éè¼Æ£¬£¬£¬£¬£¬£¬´îÔØstake¹ÙÍøÍøÂçRGOS11.XÄ£¿£¿£¿£¿£¿£¿£¿£¿é»¯²Ù×÷ϵͳ£¬£¬£¬£¬£¬£¬¿ÉÌṩ¸ü´óµÄ×ÊÔ´±íÏî¡¢¸ü¿ìµÄÓ²¼þ´¦Öóͷ£ÐÔÄÜ¡¢¸ü¸ßµÄ²Ù×÷ʹÓÃÌåÑé¡£¡£ ¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁн»Á÷»úÎªÔ°ÇøÍøÂç½ÓÈë×°±¸ÌṩǧÕ×µ½×ÀÃæÓ¦Ó㬣¬£¬£¬£¬£¬Í¬Ê±Ìṩ´óÈÝÁ¿µÄǧÕ׺ÍÍòÕ×ÉÏÐдø¿í£¬£¬£¬£¬£¬£¬Öª×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔöÌíµÄÐèÒª¡£¡£ ¡£¡£¡£¡£¡£¡£

²úÆ·ÌØÕ÷

ÍêÉÆµÄÇå¾²·À»¤Õ½ÂÔ

×Ô¶¯·ÀÓùÍøÂçÖеÄÖÖÖÖDDoS¹¥»÷£¬£¬£¬£¬£¬£¬ÍøÂçÓÉÓÚÆä¿ª·ÅÐÔ£¬£¬£¬£¬£¬£¬¾­³£ÓÉÓÚÅÌËã»úѬȾ²¡¶¾£¬£¬£¬£¬£¬£¬»òÊǽÓÈëÍøÂçµÄÖ°Ô±³öÓÚÖÖÖÖÄ¿µÄ¶ÔÍøÂç×°±¸¡¢ÍøÂçÖеķþÎñÆ÷¾ÙÐй¥»÷£¬£¬£¬£¬£¬£¬µ¼ÖÂÍøÂçÎÞ·¨Õý³£Ê¹Óᣡ£ ¡£¡£¡£¡£¡£¡£½Ï³£¼ûµÄÈçARP·ººé¹¥»÷µ¼ÖÂÍø¹ØÎÞ·¨ÏìÓ¦ÇëÇó¡¢ICMP·ººé¹¥»÷µ¼ÖÂÍøÂç×°±¸CPU¸ºÔعý¸ßÎÞ·¨Õý³£ÊÂÇ飬£¬£¬£¬£¬£¬DHCPÇëÇ󷺺鹥»÷£¬£¬£¬£¬£¬£¬µ¼ÖÂDHCP·þÎñÆ÷µØÖ·¿Ý½ß£¬£¬£¬£¬£¬£¬Óû§ÎÞ·¨Õý³£»£»£»£»£»£»ñÈ¡IPµØÖ·»á¼ûÍøÂç¡£¡£ ¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÌṩÏȽøµÄÓ²¼þCPU±£»£»£»£»£»£»¤»úÖÆ£ºÌØÓеÄCPU±£»£»£»£»£»£»¤Õ½ÂÔ£¨CPP£¬£¬£¬£¬£¬£¬CPU Protect Policy£©£¬£¬£¬£¬£¬£¬¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷£¬£¬£¬£¬£¬£¬¾ÙÐÐÁ÷Çø·ÖºÍÓÅÏȼ¶ÐÐÁзּ¶´¦Öóͷ££¬£¬£¬£¬£¬£¬²¢Æ¾Ö¤ÐèҪʵÑé´øÍÑÆÚËÙ£¬£¬£¬£¬£¬£¬³ä·Ö±£»£»£»£»£»£»¤CPU²»±»²»·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´ÏûºÄ£¬£¬£¬£¬£¬£¬°ü¹ÜÁËCPUÇå¾²£¬£¬£¬£¬£¬£¬³ä·Ö±£»£»£»£»£»£»¤Á˽»Á÷»úµÄÇå¾²¡£¡£ ¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÌṩÏȽøµÄ»ù´¡ÍøÂç±£»£»£»£»£»£»¤Õ½ÂÔ£¨NFPP£¬£¬£¬£¬£¬£¬Network Foundation Protection Policy£©ÊÖÒÕ£¬£¬£¬£¬£¬£¬Äܹ»ÏÞÖÆÓû§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÇëÇó±¨ÎÄ¡¢DHCPÇëÇó±¨ÎĵÈÊý¾Ý°üµÄÊýÂÊ£¬£¬£¬£¬£¬£¬¶ÔÁè¼ÝÏÞËÙãÐÖµµÄ±¨ÎľÙÐÐÑïÆú´¦Öóͷ££¬£¬£¬£¬£¬£¬ÉõÖÁÄܹ»Ê¶±ð¹¥»÷ÐÐΪ£¬£¬£¬£¬£¬£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§¾ÙÐиôÀë¡£¡£ ¡£¡£¡£¡£¡£¡£´Ó¶ø±£»£»£»£»£»£»¤»ù´¡ÍøÂçÃâÊÜÍøÂç¹¥»÷ÐÐΪµÄÓ°Ï죬£¬£¬£¬£¬£¬°ü¹ÜÍøÂçÎȹÌ¡£¡£ ¡£¡£¡£¡£¡£¡£

Ö§³ÖDHCP snooping£¬£¬£¬£¬£¬£¬¿ÉÖ»ÔÊÐíÐÅÈζ˿ڵÄDHCPÏìÓ¦£¬£¬£¬£¬£¬£¬±ÜÃâ˽ÉèDHCP ServerµÄÓÕÆ­£»£»£»£»£»£»²¢ÔÚDHCP¼àÌýµÄ»ù´¡ÉÏ£¬£¬£¬£¬£¬£¬Í¨¹ý¶¯Ì¬¼à²âARPºÍ¼ì²éÓû§µÄIP£¬£¬£¬£¬£¬£¬Ö±½ÓÑïÆú²»Çкϰ󶨱íÏîµÄ²»·¨±¨ÎÄ£¬£¬£¬£¬£¬£¬ÓÐÓÃÌá·ÀARPÓÕÆ­ºÍÓû§Ô´IPµØÖ·µÄÓÕÆ­ÎÊÌâ¡£¡£ ¡£¡£¡£¡£¡£¡£

ÐéÄâ½»Á÷µ¥Î»

RG-S5000ϵÁвúÆ·Ö§³ÖVSU£¨Virtual Switching Unit£¬£¬£¬£¬£¬£¬ÐéÄâ½»Á÷µ¥Î»£©£¬£¬£¬£¬£¬£¬Äܹ»½«¶ą̀ÎïÀí×°±¸¾ÙÐл¥Áª£¬£¬£¬£¬£¬£¬Ê¹ÆäÐéÄâΪһ̨Âß¼­×°±¸£¬£¬£¬£¬£¬£¬Ê¹Óüòµ¥IPµØÖ·¡¢¼òµ¥TelnetÀú³Ì¡¢¼òµ¥ÏÂÁîÐнӿڡ¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÉèÖõÈÌØÕ÷¾ÙÐйÜÀí£¬£¬£¬£¬£¬£¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚ¹ÜÀíһ̨װ±¸£¬£¬£¬£¬£¬£¬¿ÉÊÇȴʵÏÖ×Ŷą̀װ±¸´øÀ´µÄÊÂÇéЧÂʺÍʹÓÃÌåÑé¡£¡£ ¡£¡£¡£¡£¡£¡£

¼ò»¯¹ÜÀí£º¹ÜÀíÔ±¿ÉÒÔ¶Ô¶ą̀½»Á÷»úͳһ¹ÜÀí£¬£¬£¬£¬£¬£¬¶ø²»ÐèÒªÅþÁ¬µ½Ã¿Ì¨½»Á÷»ú»®·Ö¾ÙÐÐÉèÖú͹ÜÀí¡£¡£ ¡£¡£¡£¡£¡£¡£

¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨½»Á÷»ú£¬£¬£¬£¬£¬£¬Í¨¹ý¾ÛºÏÁ´Â·ºÍÍâΧװ±¸ÅþÁ¬£¬£¬£¬£¬£¬£¬²»±£´æ¶þ²ã»·Â·£¬£¬£¬£¬£¬£¬Ã»ÐëÒªÉèÖÃMSTPЭÒ飬£¬£¬£¬£¬£¬ÖÖÖÖ¿ØÖÆÐ­ÒéÊÇ×÷Ϊһ̨½»Á÷»úÔËÐеÄ¡£¡£ ¡£¡£¡£¡£¡£¡£

ºÁÃë¼¶¹ÊÕϻָ´£ºVSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬£¬£¬£¬£¬£¬£¬ÈôÊÇÆäÖÐһ̨װ±¸»òÕßÒ»Ìõ³ÉÔ±Á´Â··ºÆð¹ÊÕÏ£¬£¬£¬£¬£¬£¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄʱ¼äÖ»ÐèÒªºÁÃë¼¶¡£¡£ ¡£¡£¡£¡£¡£¡£

¸ßÀ©Õ¹ÐÔ£ºÓû§ÐÂÔöµÄ×°±¸¼ÓÈë»òÍÑÀëÐéÄâ»¯ÍøÂçʱ¿ÉÒÔʵÏÖ¡°ÈȲå°Î¡±£¬£¬£¬£¬£¬£¬²»Ó°ÏìÆäËû×°±¸µÄÕý³£ÔËÐС£¡£ ¡£¡£¡£¡£¡£¡£

±£»£»£»£»£»£»¤Í¶×Ê£ºVSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬£¬£¬£¬£¬£¬£¬¼ÈÌṩÁËÈßÓàÁ´Â·£¬£¬£¬£¬£¬£¬ÓÖ¿ÉÒÔʵÏÖ¸ºÔØÆ½ºâ£¬£¬£¬£¬£¬£¬³ä·ÖʹÓÃËùÓÐÍøÂç×°±¸ºÍ´ø¿í×ÊÔ´¡£¡£ ¡£¡£¡£¡£¡£¡£

¸ß¿É¿¿ÐÔ

¶àÀú³ÌÄ£¿£¿£¿£¿£¿£¿£¿£¿é»¯²Ù×÷ϵͳRGOS 11.X£¬£¬£¬£¬£¬£¬×é¼þ(Àú³Ì)Ï໥×ÔÁ¦£¬£¬£¬£¬£¬£¬Ò»¸ö×é¼þ(Àú³Ì)Í߽ⲻ»áÓ°Ïìµ½ÆäËû×é¼þ£¬£¬£¬£¬£¬£¬Ö§³ÖÕë¶Ô¼òµ¥Ä£¿£¿£¿£¿£¿£¿£¿£¿é´òÈȲ¹¶¡£¡£ ¡£¡£¡£¡£¡£¡£¬£¬£¬£¬£¬£¬¹ÊÕÏÄ£¿£¿£¿£¿£¿£¿£¿£¿éÉý¼¶Öв»Ó°ÏìÆäËûÀú³ÌµÄÕý³£ÔËÐкÍӪҵת·¢¡£¡£ ¡£¡£¡£¡£¡£¡£

Ö§³ÖÌìÉúÊ÷ЭÒé802.1D¡¢802.1w¡¢802.1s£¬£¬£¬£¬£¬£¬°ü¹Ü¿ìËÙÊÕÁ²£¬£¬£¬£¬£¬£¬Ìá¸ßÈÝ´íÄÜÁ¦£¬£¬£¬£¬£¬£¬°ü¹ÜÍøÂçµÄÎȹÌÔËÐкÍÁ´Â·µÄ¸ºÔØÆ½ºâ£¬£¬£¬£¬£¬£¬ºÏÀíʹÓÃÍøÂçͨµÀ£¬£¬£¬£¬£¬£¬ÌṩÈßÓàÁ´Â·Ê¹ÓÃÂÊ¡£¡£ ¡£¡£¡£¡£¡£¡£

Ö§³Ö¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£¬£¬£¬£¬£¬£¬Rapid Link Detection Protocol£©£¬£¬£¬£¬£¬£¬¿É¿ìËÙ¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ£¬£¬£¬£¬£¬£¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²â¹¦Ð§£¬£¬£¬£¬£¬£¬±ÜÃâ¶Ë¿ÚÏÂÒò˽½ÓHubµÈ×°±¸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵÄÕ÷Ï󡣡£ ¡£¡£¡£¡£¡£¡£

Ö§³Ö¹«ÓÐÒÔÌ«Íø¶à»·±£»£»£»£»£»£»¤ÊÖÒÕ£¨ERPS£©£¬£¬£¬£¬£¬£¬¹ú¼Ê±ê׼Ϊ½¹µãÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝЭÒ飬£¬£¬£¬£¬£¬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·»Ö¸´¶¼¼¯ÖÐÔÚÖ÷¿Ø×°±¸ÉϾÙÐУ¬£¬£¬£¬£¬£¬·ÇÖ÷¿Ø×°±¸Ö±½ÓÏòÖ÷¿Ø×°±¸»ã±¨×Ô¼ºµÄÁ´Â·ÇéÐΣ¬£¬£¬£¬£¬£¬ÎÞÐè¾­ÓÉÆäËû·ÇÖ÷¿Ø×°±¸µÄ´¦Öóͷ££¬£¬£¬£¬£¬£¬Òò´Ë»·Â·ÖÐÖ¹ÒÔ¼°»Ö¸´Ê±¼ä±ÈSTP¿ì¡£¡£ ¡£¡£¡£¡£¡£¡£»£»£»£»£»£»ùÓÚÒÔÉÏÇø±ð£¬£¬£¬£¬£¬£¬ERPSÔÚÀíÏëÇéÐÎϵÄÁ´Â·»Ö¸´ÄÜÁ¦Äܹ»µÖ´ïºÁÃë¼¶¡£¡£ ¡£¡£¡£¡£¡£¡£

Ö§³Ö¿ìËÙÒÔÌ«ÍøÉÏÁ´±£»£»£»£»£»£»¤Ð­Ò飨REUP£¬£¬£¬£¬£¬£¬Rapid Ethernet Uplink Protection£©£¬£¬£¬£¬£¬£¬ÔÚ²»ÆôÓÃSTPµÄÇéÐÎÏ£¬£¬£¬£¬£¬£¬¿ÉÒÔÌṩһ¸ö¿ìËÙÉÏÁ´±£»£»£»£»£»£»¤¹¦Ð§£¬£¬£¬£¬£¬£¬REUPʹµÃÓû§ÔڹرÕSTPµÄÇéÐÎÏ£¬£¬£¬£¬£¬£¬ÈÔÌṩ»ù±¾µÄÁ´Â·ÈßÓ࣬£¬£¬£¬£¬£¬Í¬Ê±Ìṩ±ÈSTP¸ü¿ìµÄºÁÃë¼¶¹ÊÕϻָ´¡£¡£ ¡£¡£¡£¡£¡£¡£

ÂÌÉ«½ÚÄÜ

RG-S5000ϵÁн»Á÷»ú³ä·ÖÏìÓ¦¹ú¼ÒÂÌÉ«½ÚÄܵÄÕкô£¬£¬£¬£¬£¬£¬½ÓÄɶàÖÖÂÌÉ«½ÚÄܵÄÉè¼ÆÀíÄ£¬£¬£¬£¬£¬Õë¶Ô¹Å°å½»Á÷»úÔÚÔëÒô¼°Äܺķ½Ãæ±£´æµÄÎÊÌâ¾ÙÐÐÉîÈëÑо¿Ì½Ë÷£¬£¬£¬£¬£¬£¬³ä·Ö½â¾öÁ˽»Á÷»ú°²ÅÅÔڰ칫ÇéÐÎÔëÉù´ó¡¢ÒÔ¼°½ÓÈë×°±¸´óÅúÁ¿°²Åźó´øÀ´µÄÄܺĹý´óµÄÎÊÌâ¡£¡£ ¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁн»Á÷»ú½ÓÄÉÁËÐÂÒ»´úµÄÓ²¼þ¼Ü¹¹ÒÔ¼°ÏȽøµÄ½ÚÄܵç·Éè¼ÆºÍÔªÆ÷¼þÑ¡ÐÍ£¬£¬£¬£¬£¬£¬ÎªÓû§½ÚÔ¼Äܺ쬣¬£¬£¬£¬£¬Í¬Ê±½µµÍÔëÒôÎÛȾ¡£¡£ ¡£¡£¡£¡£¡£¡£

RG-S5000Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬£¬£¬£¬£¬£¬¶Ë¿ÚÈôÊÇÔÚÒ»Á¬Ò»¶Îʱ¼äÖ®ÄÚ¿ÕÏУ¬£¬£¬£¬£¬£¬ÏµÍ³»á½«¸Ã¶Ë¿ÚÉèÖÃΪ½ÚÄÜģʽ£¬£¬£¬£¬£¬£¬µ±Óб¨ÎÄÊÕ·¢Ê±ÔÙͨ¹ý׼ʱ·¢Ë͵ļàÌýÂëÁ÷½ÐÐѶ˿ڻָ´ÓªÒµ£¬£¬£¬£¬£¬£¬µÖ´ï½ÚÄܵÄЧ¹û¡£¡£ ¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁвúƷͬʱ֪×ãÖÊÁÏ»·±£ÓëÇå¾²ÐÔµÄÅ·ÃËRoHS±ê×¼¡£¡£ ¡£¡£¡£¡£¡£¡£

¼òÆÓÇáËɵÄÍøÂçά»¤

RG-S5000ϵÁÐÖ§³ÖÔÆ¹ÜÀí£¬£¬£¬£¬£¬£¬¿ÉÒÔ´ø¸ø¿Í»§¼«¼òµÄÔËά¹ÜÀíºÍÓû§ÌåÑé¡£¡£ ¡£¡£¡£¡£¡£¡£

Ò××éÍø£ºÖ»ÐèҪһ̨ÄÜÉÏÍøµÄPC»òÕßÊÖ»ú£¬£¬£¬£¬£¬£¬¼´¿ÉÍê³É°²ÅÅ£¬£¬£¬£¬£¬£¬¼´²å¼´Óᣡ£ ¡£¡£¡£¡£¡£¡£Ö§³Ö»ùÓÚÍø¹ØµÄÍøÂçÍØÆË×Ô¶¯·¢Ã÷£¬£¬£¬£¬£¬£¬²¢ÒÔͼÐλ¯ÐÎʽ·ºÆð

Ò×ÔËά£ºÔËά¼òÆÓ£¬£¬£¬£¬£¬£¬ÍøÂçËæÊ±¿É¹Ü£¬£¬£¬£¬£¬£¬ÈËÔÚÄÇÀïÍøÂç¾ÍÔÚÄÇÀ£¬£¬£¬£¬£¬ÓÐÏßÎÞÏßÍø¹Ø¾¡ÔÚÕÆÎÕÖС£¡£ ¡£¡£¡£¡£¡£¡£Ö§³ÖÉèÖÃÏ·¢¡¢ÉèÖñ¸·Ý¡¢ÉèÖûָ´¡¢ÏÂÁîµ÷ÊÔ¡¢»á¼ûeWeb¡¢»á¼ûTelnet¡¢»á¼ûSSH¡¢ÖØÆô¡¢×°±¸Éý¼¶

Ò×¼à¿Ø£º¿ÉËæÊ±Éó²éÍøÂ翵½¡¶È£¬£¬£¬£¬£¬£¬×°±¸ÏêÇé(ϵͳ״̬¡¢Á÷Á¿×ßÊÆ¡¢Á¬Í¨ÐÔ¡¢¹©µç״̬µÈ)£¬£¬£¬£¬£¬£¬¹ÊÕÏ¿ÉÊÓ£¬£¬£¬£¬£¬£¬Óû§ÍøÂçÌåÑé¿ÉÊÓ£¬£¬£¬£¬£¬£¬ÓÐ¸æ¾¯ÊµÊ±ÍÆËÍ£¬£¬£¬£¬£¬£¬ÓÐÈÕÖ¾ÊÂÎñ¹©»ØËÝ¡£¡£ ¡£¡£¡£¡£¡£¡£Ö§³Ö¸æ¾¯¿Éͨ¹ý΢ÐŹ«Öںš¢Óʼþ¡¢Î¢ÐÅ¡¢ÆóÒµ¶¤¶¤·¢ËÍÌáÐÑ

Ò×ÈÏÖ¤£ºÒÀÍÐÔÆ¶Ë£¬£¬£¬£¬£¬£¬ÕûÍø±ãÄÜÌṩÉÏÍøÊµÃûÈÏÖ¤£¬£¬£¬£¬£¬£¬²»±ØÈκεĸ½¼ÓÈí¼þºÍ·þÎñÆ÷¡£¡£ ¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÖ§³ÖSNMP¡¢RMON¡¢SyslogµÈÌØÕ÷À´¾ÙÐÐÍøÂçµÄÒ»Ñùƽ³£Õï¶Ï¼°Î¬»¤£¬£¬£¬£¬£¬£¬Í¬Ê±¹ÜÀíÔ±¿É½ÓÄÉCLI(ÏÂÁîÐнӿÚ)¡¢WebÍø¹Ü¡¢TelnetµÈ¶àÑù»¯µÄ¹ÜÀíºÍά»¤·½·¨¸üÀû±ã×°±¸µÄ¹ÜÀí¡£¡£ ¡£¡£¡£¡£¡£¡£?

Ö§³ÖSDN¿ØÖÆÆ÷ͳһÄɹܣ¬£¬£¬£¬£¬£¬¼ò»¯ÍøÂç¹ÜÀí£¬£¬£¬£¬£¬£¬½µµÍÍøÂçά»¤±¾Ç®¡£¡£ ¡£¡£¡£¡£¡£¡£

PoEʹÓÃ״̬һĿÁËÈ»£ºÃæ°å×Ô´øÒ»¼üÉó²éPoE¹©µç״̬¹¦Ð§µÄPoE°´Å¥£¬£¬£¬£¬£¬£¬Çá°´¼´¿ÉÉó²é×°±¸Ä¿½ñµÄͨѶ״̬ºÍ¹©µç״̬£¬£¬£¬£¬£¬£¬ÈÃÄú¶ÔËùÓж˿ÚPoE¹©µçµÄ״̬ÁËÈ»ÓÚÐÄ¡£¡£ ¡£¡£¡£¡£¡£¡£

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

ϵͳ¹æ¸ñ

ϵͳ¹æ¸ñ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
½»Á÷ÈÝÁ¿ 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 171Mpps 207Mpps 171Mpps 171Mpps 171Mpps
PoE¹©µç±ê×¼ ²»Ö§³Ö Ö§³ÖPoE/PoE+

½Ó¿ÚÓëÄ£¿£¿£¿£¿£¿£¿£¿£¿é

½Ó¿ÚÓëÄ£¿£¿£¿£¿£¿£¿£¿£¿é RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
¹Ì»¯ÓªÒµ½Ó¿Ú 4¸ö1G SFP½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö1G SFP½Ó¿Ú
24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 48¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú
¹Ì»¯¹ÜÀí½Ó¿Ú 1¸öRJ45 Console½Ó¿Ú
¹Ì»¯µçÔ´ÊýÄ¿ 1
¹Ì»¯µçÉÈÊýÄ¿ 1

µçÔ´Ó빦ºÄ

µçÔ´Ó빦ºÄ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
Õû»ú×î´ó¹¦ºÄ 24W 40W 24W 40W£¨²»´øPoE¸ºÔØ£© 40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£© 460W£¨PoEÂúÔØ£©
¶î¶¨ÊäÈëµçѹ¹æÄ£ 100Vac~240Vac,47~63Hz 100Vac~240Vac,47~63Hz 100Vac~240Vac,47~63Hz 100V AC~240V AC£¬£¬£¬£¬£¬£¬50~60Hz
127V ~386Vdc 127V ~410Vdc 127V ~386Vdc 192V DC~290V DC
×î´óÊäÈëµçѹ¹æÄ£ 90V AC~264V AC£¬£¬£¬£¬£¬£¬47~63Hz 90V AC~264V AC£¬£¬£¬£¬£¬£¬47~63Hz 90V AC~264V AC£¬£¬£¬£¬£¬£¬47~63Hz 90V AC~264V AC£¬£¬£¬£¬£¬£¬50~60Hz
¶î¶¨ÊäÈëµçÁ÷ 0.6A 1.5A 0.6A 6.8A 6.8A

³ß´çÓëÖØÁ¿

³ß´çÓëÖØÁ¿ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 440mm x 220mm x 44mm
440mm x 220mm x 44mm
V2.XX°æ±¾£º440mm x 220mm x 43.6mm
ÖØÁ¿ 2.45kg 2.83kg 2.45kg 3.8kg 3.8kg
»ú¼Ü³ß´ç 1RU
×°Ö÷½·¨ ×ÀÃæ/±Ú¹Ò/»ú¼Ü£¨¹ñ£©

ÇéÐÎÓë¿É¿¿ÐÔ

ÇéÐÎÓë¿É¿¿ÐÔ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
ÏßÀÂÈȲå°Î Console¿Ú¡¢ÓªÒµ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö
ÎÂ¶È ÊÂÇéζȣº0°C~50°C
´æ´¢Î¶ȣº-40°C~70°C
º£°Î1800~5000m£ºº£°ÎÿÉý¸ß100m£¬£¬£¬£¬£¬£¬×î¸ßζȹæ¸ñ½µµÍ0.6¡æ
ʪ¶È ÊÂÇéʪ¶È£º10%RH~90%RH
´æ´¢Êª¶È£º5%RH~95%RH
ÔëÉù £¼45dBA £¼45dBA £¼45dBA £¼78dBA £¼78dBA
É¢ÈÈ ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬£¬²à½øºó³ö ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬£¬²à½øºó³ö
ÎÂ¶È¼à¿Ø ÎÂ¶È¼à¿Ø£ºÖ§³Ö
ζȸ澯£ºÖ§³Ö
¹ýα£»£»£»£»£»£»¤£ºÖ§³Ö
µçÉÈ¼à¿Ø ²»Éæ¼° ¹ÊÕϸ澯£ºÖ§³Ö
ÊÖ¶¯µ÷ËÙ£º²»Ö§³Ö
ÖÇÄܵ÷ËÙ£ºÖ§³Ö
Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§
µçÔ´¼à¿Ø ²»Éæ¼° Ä£¿£¿£¿£¿£¿£¿£¿£¿é¼à¿Ø£º²»Ö§³Ö
¹ÊÕϸ澯£ºÖ§³Ö
ÖÇÄÜÉϵ磺²»Ö§³Ö
·ÀÀ× 10kV

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S5000-24GT4SFP/ RG-S5000-24GT4XS RG-S5000-48GT4XS RG-S5000-24GT4SFP-P/ RG-S5000-24GT4XS-P
PoE ²»Ö§³Ö ²»Ö§³Ö ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¼æÈݷDZê×¼PD×°±¸
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
MACµØÖ·±í Ö§³Ö¾²Ì¬MACµØÖ·
Ö§³ÖMACµØÖ·¹ýÂË
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö»ù±¾QinQ
Ö§³ÖÎÞаQinQ
¶þ²ã»·ÍøÊÖÒÕ Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS£¬£¬£¬£¬£¬£¬Çл»Ê±¼ä≤200ms£¬£¬£¬£¬£¬£¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·¼æÈÝ
¶Ë¿Ú¾ÛºÏ Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨
Ö§³ÖLACP¶¯Ì¬¾ÛºÏ
Ö§³ÖLACPÓÅÏȼ¶/ЭÉÌ·½·¨ /×î´ó¿É¾ÛºÏ¿ÚÊýÄ¿ÉèÖÃ
Ö§³Ö¿çVSU AP
Mirror Ö§³ÖͨË×ÓªÒµ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú
Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄÍâµØºÍÔ¶³Ì¾µÏñ
Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ
Ö§³ÖRSPANºÍERSPAN
Ö§³Ö¿ç×°±¸µÄÁ÷Á¿¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
VSUÌØÕ÷ Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ
IP·ÓÉ IPv4/IPv6¾²Ì¬Â·ÓÉ¡¢Ö§³ÖRIP¡¢RIPng¡¢OSPF¡¢OSPFv3ЭÒé
ACL Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©
IP·ÓÉ Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
ACL
QoS
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³ÖACL80
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACLÖØ¶¨Ïò
Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
QoS
Çå¾²ÌØÕ÷
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí
¹ýÂ˲»·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»£»£»£»£»£»¤
Çå¾²ÌØÕ÷
EEE
¹ÜÀíÌØÕ÷
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»£»£»£»£»£»¤
Ö§³ÖIEEE 802.3az±ê×¼µÄEEE£¨Energy Efficient Ethernet£¬£¬£¬£¬£¬£¬½ÚÄÜÒÔÌ«Íø£©ÊÖÒÕ
SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢WIS¹«ÓÐÔÆÆ½Ì¨¹ÜÀí
Õö¿ªÏêϸ²ÎÊý

³£¼ûÎÊÌâ

ÔÝÎÞÎÊÌ⣬£¬£¬£¬£¬£¬ÎÒÒªÌáÎÊ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿£¿£¿£¿£¿£¿£¿£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿£¿£¿£¿£¿£¿£¿£¿
Á¬Ã¦×Éѯ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾ ÎĵµAIÖúÊÖ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿£¿£¿£¿£¿£¿£¿£¿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿£¿£¿£¿£¿£¿£¿£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£¡£ ¡£¡£¡£¡£¡£¡£©£¿£¿£¿£¿£¿£¿£¿£¿
Äú¶ÔÎĵµÊÇ·ñÉÐÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿£¿£¿£¿£¿£¿£¿£¿
Ϊ¾¡¿ì½â¾öÎÊÌ⣬£¬£¬£¬£¬£¬ÇëÄúÁôÏÂÁªÏµ·½·¨Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À¡£¡£ ¡£¡£¡£¡£¡£¡£¡
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼