stake¹ÙÍø

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·£¬£¬£¬£¬£¬ £¬£¬£¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¬Ã¦ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
RG-S5000-24GT4XS-P
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

24¿ÚǧÕ×Èý²ãºÐʽ½ÓÈë²ãPoE½»Á÷»ú£¬£¬£¬£¬£¬ £¬£¬£¬ÍòÕ×ÉÏÐУ¬£¬£¬£¬£¬ £¬£¬£¬RG-S5000-24GT4XS-P

ÎªÔ°ÇøÍøÂç½ÓÈë×°±¸ÌṩǧÕ×µ½×ÀÃæµÄÓ¦Ó㬣¬£¬£¬£¬ £¬£¬£¬Í¬Ê±Ìṩ´óÈÝÁ¿µÄÍòÕ×ÉÏÐдø¿í£¬£¬£¬£¬£¬ £¬£¬£¬Öª×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔöÌíµÄÐèÒª

²úÆ·ÌØÕ÷£º

  • 24¸ö10/100/1000Base-TÒÔÌ«Íø¿Ú£¬£¬£¬£¬£¬ £¬£¬£¬Ö§³ÖPoE+
  • 4¸ö×ÔÁ¦ÍòÕ×SFP+¹â¿Ú
  • Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ£¬£¬£¬£¬£¬ £¬£¬£¬¼ò»¯ÍøÂç¹ÜÀí
  • Ö§³ÖCPP/NFPP/RLDP/DHCP snooping¶àÖØÇå¾²·À»¤Õ½ÂÔ
  • ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬ £¬£¬£¬ÖÇÄܵ÷ËÙ£¬£¬£¬£¬£¬ £¬£¬£¬µÍÔëÇÒ½ÚÄÜ
Á¬Ã¦×Éѯ

²úÆ·¸ÅÊö

RG-S5000ϵÁн»Á÷»úÊÇstake¹ÙÍøÍøÂçÃæÏòÖÐÐ¡Ô°ÇøÍÆ³öµÄǧÕ×ÒÔÌ«Íø½»Á÷»ú¡£ ¡£¡£¡£¡£¡£¸ÃϵÁвúÆ·½ÓÄÉȫеÄÓ²¼þ¼Ü¹¹Éè¼Æ£¬£¬£¬£¬£¬ £¬£¬£¬´îÔØstake¹ÙÍøÍøÂçRGOS11.XÄ£¿ £¿£¿£¿£¿£¿£¿é»¯²Ù×÷ϵͳ£¬£¬£¬£¬£¬ £¬£¬£¬¿ÉÌṩ¸ü´óµÄ×ÊÔ´±íÏî¡¢¸ü¿ìµÄÓ²¼þ´¦Öóͷ£ÐÔÄÜ¡¢¸ü¸ßµÄ²Ù×÷ʹÓÃÌåÑé¡£ ¡£¡£¡£¡£¡£

RG-S5000ϵÁн»Á÷»úÎªÔ°ÇøÍøÂç½ÓÈë×°±¸ÌṩǧÕ×µ½×ÀÃæÓ¦Ó㬣¬£¬£¬£¬ £¬£¬£¬Í¬Ê±Ìṩ´óÈÝÁ¿µÄǧÕ׺ÍÍòÕ×ÉÏÐдø¿í£¬£¬£¬£¬£¬ £¬£¬£¬Öª×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔöÌíµÄÐèÒª¡£ ¡£¡£¡£¡£¡£

²úÆ·ÌØÕ÷

ÍêÉÆµÄÇå¾²·À»¤Õ½ÂÔ

×Ô¶¯·ÀÓùÍøÂçÖеÄÖÖÖÖDDoS¹¥»÷£¬£¬£¬£¬£¬ £¬£¬£¬ÍøÂçÓÉÓÚÆä¿ª·ÅÐÔ£¬£¬£¬£¬£¬ £¬£¬£¬¾­³£ÓÉÓÚÅÌËã»úѬȾ²¡¶¾£¬£¬£¬£¬£¬ £¬£¬£¬»òÊǽÓÈëÍøÂçµÄÖ°Ô±³öÓÚÖÖÖÖÄ¿µÄ¶ÔÍøÂç×°±¸¡¢ÍøÂçÖеķþÎñÆ÷¾ÙÐй¥»÷£¬£¬£¬£¬£¬ £¬£¬£¬µ¼ÖÂÍøÂçÎÞ·¨Õý³£Ê¹Óᣠ¡£¡£¡£¡£¡£½Ï³£¼ûµÄÈçARP·ººé¹¥»÷µ¼ÖÂÍø¹ØÎÞ·¨ÏìÓ¦ÇëÇó¡¢ICMP·ººé¹¥»÷µ¼ÖÂÍøÂç×°±¸CPU¸ºÔعý¸ßÎÞ·¨Õý³£ÊÂÇ飬£¬£¬£¬£¬ £¬£¬£¬DHCPÇëÇ󷺺鹥»÷£¬£¬£¬£¬£¬ £¬£¬£¬µ¼ÖÂDHCP·þÎñÆ÷µØÖ·¿Ý½ß£¬£¬£¬£¬£¬ £¬£¬£¬Óû§ÎÞ·¨Õý³£»£»£»£»£»£»ñÈ¡IPµØÖ·»á¼ûÍøÂç¡£ ¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÌṩÏȽøµÄÓ²¼þCPU±£»£»£»£»£»£»¤»úÖÆ£ºÌØÓеÄCPU±£»£»£»£»£»£»¤Õ½ÂÔ£¨CPP£¬£¬£¬£¬£¬ £¬£¬£¬CPU Protect Policy£©£¬£¬£¬£¬£¬ £¬£¬£¬¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷£¬£¬£¬£¬£¬ £¬£¬£¬¾ÙÐÐÁ÷Çø·ÖºÍÓÅÏȼ¶ÐÐÁзּ¶´¦Öóͷ££¬£¬£¬£¬£¬ £¬£¬£¬²¢Æ¾Ö¤ÐèҪʵÑé´øÍÑÆÚËÙ£¬£¬£¬£¬£¬ £¬£¬£¬³ä·Ö±£»£»£»£»£»£»¤CPU²»±»²»·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´ÏûºÄ£¬£¬£¬£¬£¬ £¬£¬£¬°ü¹ÜÁËCPUÇå¾²£¬£¬£¬£¬£¬ £¬£¬£¬³ä·Ö±£»£»£»£»£»£»¤Á˽»Á÷»úµÄÇå¾²¡£ ¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÌṩÏȽøµÄ»ù´¡ÍøÂç±£»£»£»£»£»£»¤Õ½ÂÔ£¨NFPP£¬£¬£¬£¬£¬ £¬£¬£¬Network Foundation Protection Policy£©ÊÖÒÕ£¬£¬£¬£¬£¬ £¬£¬£¬Äܹ»ÏÞÖÆÓû§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÇëÇó±¨ÎÄ¡¢DHCPÇëÇó±¨ÎĵÈÊý¾Ý°üµÄÊýÂÊ£¬£¬£¬£¬£¬ £¬£¬£¬¶ÔÁè¼ÝÏÞËÙãÐÖµµÄ±¨ÎľÙÐÐÑïÆú´¦Öóͷ££¬£¬£¬£¬£¬ £¬£¬£¬ÉõÖÁÄܹ»Ê¶±ð¹¥»÷ÐÐΪ£¬£¬£¬£¬£¬ £¬£¬£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§¾ÙÐиôÀë¡£ ¡£¡£¡£¡£¡£´Ó¶ø±£»£»£»£»£»£»¤»ù´¡ÍøÂçÃâÊÜÍøÂç¹¥»÷ÐÐΪµÄÓ°Ï죬£¬£¬£¬£¬ £¬£¬£¬°ü¹ÜÍøÂçÎȹ̡£ ¡£¡£¡£¡£¡£

Ö§³ÖDHCP snooping£¬£¬£¬£¬£¬ £¬£¬£¬¿ÉÖ»ÔÊÐíÐÅÈζ˿ڵÄDHCPÏìÓ¦£¬£¬£¬£¬£¬ £¬£¬£¬±ÜÃâ˽ÉèDHCP ServerµÄÓÕÆ­£»£»£»£»£»£»²¢ÔÚDHCP¼àÌýµÄ»ù´¡ÉÏ£¬£¬£¬£¬£¬ £¬£¬£¬Í¨¹ý¶¯Ì¬¼à²âARPºÍ¼ì²éÓû§µÄIP£¬£¬£¬£¬£¬ £¬£¬£¬Ö±½ÓÑïÆú²»Çкϰ󶨱íÏîµÄ²»·¨±¨ÎÄ£¬£¬£¬£¬£¬ £¬£¬£¬ÓÐÓÃÌá·ÀARPÓÕÆ­ºÍÓû§Ô´IPµØÖ·µÄÓÕÆ­ÎÊÌâ¡£ ¡£¡£¡£¡£¡£

ÐéÄâ½»Á÷µ¥Î»

RG-S5000ϵÁвúÆ·Ö§³ÖVSU£¨Virtual Switching Unit£¬£¬£¬£¬£¬ £¬£¬£¬ÐéÄâ½»Á÷µ¥Î»£©£¬£¬£¬£¬£¬ £¬£¬£¬Äܹ»½«¶ą̀ÎïÀí×°±¸¾ÙÐл¥Áª£¬£¬£¬£¬£¬ £¬£¬£¬Ê¹ÆäÐéÄâΪһ̨Âß¼­×°±¸£¬£¬£¬£¬£¬ £¬£¬£¬Ê¹Óüòµ¥IPµØÖ·¡¢¼òµ¥TelnetÀú³Ì¡¢¼òµ¥ÏÂÁîÐнӿڡ¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÉèÖõÈÌØÕ÷¾ÙÐйÜÀí£¬£¬£¬£¬£¬ £¬£¬£¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚ¹ÜÀíһ̨װ±¸£¬£¬£¬£¬£¬ £¬£¬£¬¿ÉÊÇȴʵÏÖ×Ŷą̀װ±¸´øÀ´µÄÊÂÇéЧÂʺÍʹÓÃÌåÑé¡£ ¡£¡£¡£¡£¡£

¼ò»¯¹ÜÀí£º¹ÜÀíÔ±¿ÉÒÔ¶Ô¶ą̀½»Á÷»úͳһ¹ÜÀí£¬£¬£¬£¬£¬ £¬£¬£¬¶ø²»ÐèÒªÅþÁ¬µ½Ã¿Ì¨½»Á÷»ú»®·Ö¾ÙÐÐÉèÖú͹ÜÀí¡£ ¡£¡£¡£¡£¡£

¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨½»Á÷»ú£¬£¬£¬£¬£¬ £¬£¬£¬Í¨¹ý¾ÛºÏÁ´Â·ºÍÍâΧװ±¸ÅþÁ¬£¬£¬£¬£¬£¬ £¬£¬£¬²»±£´æ¶þ²ã»·Â·£¬£¬£¬£¬£¬ £¬£¬£¬Ã»ÐëÒªÉèÖÃMSTPЭÒ飬£¬£¬£¬£¬ £¬£¬£¬ÖÖÖÖ¿ØÖÆÐ­ÒéÊÇ×÷Ϊһ̨½»Á÷»úÔËÐеġ£ ¡£¡£¡£¡£¡£

ºÁÃë¼¶¹ÊÕϻָ´£ºVSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬£¬£¬£¬£¬£¬ £¬£¬£¬ÈôÊÇÆäÖÐһ̨װ±¸»òÕßÒ»Ìõ³ÉÔ±Á´Â··ºÆð¹ÊÕÏ£¬£¬£¬£¬£¬ £¬£¬£¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄʱ¼äÖ»ÐèÒªºÁÃë¼¶¡£ ¡£¡£¡£¡£¡£

¸ßÀ©Õ¹ÐÔ£ºÓû§ÐÂÔöµÄ×°±¸¼ÓÈë»òÍÑÀëÐéÄâ»¯ÍøÂçʱ¿ÉÒÔʵÏÖ¡°ÈȲå°Î¡±£¬£¬£¬£¬£¬ £¬£¬£¬²»Ó°ÏìÆäËû×°±¸µÄÕý³£ÔËÐС£ ¡£¡£¡£¡£¡£

±£»£»£»£»£»£»¤Í¶×Ê£ºVSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬£¬£¬£¬£¬£¬ £¬£¬£¬¼ÈÌṩÁËÈßÓàÁ´Â·£¬£¬£¬£¬£¬ £¬£¬£¬ÓÖ¿ÉÒÔʵÏÖ¸ºÔØÆ½ºâ£¬£¬£¬£¬£¬ £¬£¬£¬³ä·ÖʹÓÃËùÓÐÍøÂç×°±¸ºÍ´ø¿í×ÊÔ´¡£ ¡£¡£¡£¡£¡£

¸ß¿É¿¿ÐÔ

¶àÀú³ÌÄ£¿ £¿£¿£¿£¿£¿£¿é»¯²Ù×÷ϵͳRGOS 11.X£¬£¬£¬£¬£¬ £¬£¬£¬×é¼þ(Àú³Ì)Ï໥×ÔÁ¦£¬£¬£¬£¬£¬ £¬£¬£¬Ò»¸ö×é¼þ(Àú³Ì)Í߽ⲻ»áÓ°Ïìµ½ÆäËû×é¼þ£¬£¬£¬£¬£¬ £¬£¬£¬Ö§³ÖÕë¶Ô¼òµ¥Ä£¿ £¿£¿£¿£¿£¿£¿é´òÈȲ¹¶¡£¬£¬£¬£¬£¬ £¬£¬£¬¹ÊÕÏÄ£¿ £¿£¿£¿£¿£¿£¿éÉý¼¶Öв»Ó°ÏìÆäËûÀú³ÌµÄÕý³£ÔËÐкÍӪҵת·¢¡£ ¡£¡£¡£¡£¡£

Ö§³ÖÌìÉúÊ÷ЭÒé802.1D¡¢802.1w¡¢802.1s£¬£¬£¬£¬£¬ £¬£¬£¬°ü¹Ü¿ìËÙÊÕÁ²£¬£¬£¬£¬£¬ £¬£¬£¬Ìá¸ßÈÝ´íÄÜÁ¦£¬£¬£¬£¬£¬ £¬£¬£¬°ü¹ÜÍøÂçµÄÎȹÌÔËÐкÍÁ´Â·µÄ¸ºÔØÆ½ºâ£¬£¬£¬£¬£¬ £¬£¬£¬ºÏÀíʹÓÃÍøÂçͨµÀ£¬£¬£¬£¬£¬ £¬£¬£¬ÌṩÈßÓàÁ´Â·Ê¹ÓÃÂÊ¡£ ¡£¡£¡£¡£¡£

Ö§³Ö¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£¬£¬£¬£¬£¬ £¬£¬£¬Rapid Link Detection Protocol£©£¬£¬£¬£¬£¬ £¬£¬£¬¿É¿ìËÙ¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ£¬£¬£¬£¬£¬ £¬£¬£¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²â¹¦Ð§£¬£¬£¬£¬£¬ £¬£¬£¬±ÜÃâ¶Ë¿ÚÏÂÒò˽½ÓHubµÈ×°±¸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵÄÕ÷Ïó¡£ ¡£¡£¡£¡£¡£

Ö§³Ö¹«ÓÐÒÔÌ«Íø¶à»·±£»£»£»£»£»£»¤ÊÖÒÕ£¨ERPS£©£¬£¬£¬£¬£¬ £¬£¬£¬¹ú¼Ê±ê׼Ϊ½¹µãÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝЭÒ飬£¬£¬£¬£¬ £¬£¬£¬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·»Ö¸´¶¼¼¯ÖÐÔÚÖ÷¿Ø×°±¸ÉϾÙÐУ¬£¬£¬£¬£¬ £¬£¬£¬·ÇÖ÷¿Ø×°±¸Ö±½ÓÏòÖ÷¿Ø×°±¸»ã±¨×Ô¼ºµÄÁ´Â·ÇéÐΣ¬£¬£¬£¬£¬ £¬£¬£¬ÎÞÐè¾­ÓÉÆäËû·ÇÖ÷¿Ø×°±¸µÄ´¦Öóͷ££¬£¬£¬£¬£¬ £¬£¬£¬Òò´Ë»·Â·ÖÐÖ¹ÒÔ¼°»Ö¸´Ê±¼ä±ÈSTP¿ì¡£ ¡£¡£¡£¡£¡£»£»£»£»£»£»ùÓÚÒÔÉÏÇø±ð£¬£¬£¬£¬£¬ £¬£¬£¬ERPSÔÚÀíÏëÇéÐÎϵÄÁ´Â·»Ö¸´ÄÜÁ¦Äܹ»µÖ´ïºÁÃë¼¶¡£ ¡£¡£¡£¡£¡£

Ö§³Ö¿ìËÙÒÔÌ«ÍøÉÏÁ´±£»£»£»£»£»£»¤Ð­Ò飨REUP£¬£¬£¬£¬£¬ £¬£¬£¬Rapid Ethernet Uplink Protection£©£¬£¬£¬£¬£¬ £¬£¬£¬ÔÚ²»ÆôÓÃSTPµÄÇéÐÎÏ£¬£¬£¬£¬£¬ £¬£¬£¬¿ÉÒÔÌṩһ¸ö¿ìËÙÉÏÁ´±£»£»£»£»£»£»¤¹¦Ð§£¬£¬£¬£¬£¬ £¬£¬£¬REUPʹµÃÓû§ÔڹرÕSTPµÄÇéÐÎÏ£¬£¬£¬£¬£¬ £¬£¬£¬ÈÔÌṩ»ù±¾µÄÁ´Â·ÈßÓ࣬£¬£¬£¬£¬ £¬£¬£¬Í¬Ê±Ìṩ±ÈSTP¸ü¿ìµÄºÁÃë¼¶¹ÊÕϻָ´¡£ ¡£¡£¡£¡£¡£

ÂÌÉ«½ÚÄÜ

RG-S5000ϵÁн»Á÷»ú³ä·ÖÏìÓ¦¹ú¼ÒÂÌÉ«½ÚÄܵÄÕкô£¬£¬£¬£¬£¬ £¬£¬£¬½ÓÄɶàÖÖÂÌÉ«½ÚÄܵÄÉè¼ÆÀíÄ£¬£¬£¬£¬ £¬£¬£¬Õë¶Ô¹Å°å½»Á÷»úÔÚÔëÒô¼°Äܺķ½Ãæ±£´æµÄÎÊÌâ¾ÙÐÐÉîÈëÑо¿Ì½Ë÷£¬£¬£¬£¬£¬ £¬£¬£¬³ä·Ö½â¾öÁ˽»Á÷»ú°²ÅÅÔڰ칫ÇéÐÎÔëÉù´ó¡¢ÒÔ¼°½ÓÈë×°±¸´óÅúÁ¿°²Åźó´øÀ´µÄÄܺĹý´óµÄÎÊÌâ¡£ ¡£¡£¡£¡£¡£

RG-S5000ϵÁн»Á÷»ú½ÓÄÉÁËÐÂÒ»´úµÄÓ²¼þ¼Ü¹¹ÒÔ¼°ÏȽøµÄ½ÚÄܵç·Éè¼ÆºÍÔªÆ÷¼þÑ¡ÐÍ£¬£¬£¬£¬£¬ £¬£¬£¬ÎªÓû§½ÚÔ¼ÄܺÄ£¬£¬£¬£¬£¬ £¬£¬£¬Í¬Ê±½µµÍÔëÒôÎÛȾ¡£ ¡£¡£¡£¡£¡£

RG-S5000Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬£¬£¬£¬£¬ £¬£¬£¬¶Ë¿ÚÈôÊÇÔÚÒ»Á¬Ò»¶Îʱ¼äÖ®ÄÚ¿ÕÏУ¬£¬£¬£¬£¬ £¬£¬£¬ÏµÍ³»á½«¸Ã¶Ë¿ÚÉèÖÃΪ½ÚÄÜģʽ£¬£¬£¬£¬£¬ £¬£¬£¬µ±Óб¨ÎÄÊÕ·¢Ê±ÔÙͨ¹ý׼ʱ·¢Ë͵ļàÌýÂëÁ÷½ÐÐѶ˿ڻָ´ÓªÒµ£¬£¬£¬£¬£¬ £¬£¬£¬µÖ´ï½ÚÄܵÄЧ¹û¡£ ¡£¡£¡£¡£¡£

RG-S5000ϵÁвúƷͬʱ֪×ãÖÊÁÏ»·±£ÓëÇå¾²ÐÔµÄÅ·ÃËRoHS±ê×¼¡£ ¡£¡£¡£¡£¡£

¼òÆÓÇáËɵÄÍøÂçά»¤

RG-S5000ϵÁÐÖ§³ÖÔÆ¹ÜÀí£¬£¬£¬£¬£¬ £¬£¬£¬¿ÉÒÔ´ø¸ø¿Í»§¼«¼òµÄÔËά¹ÜÀíºÍÓû§ÌåÑé¡£ ¡£¡£¡£¡£¡£

Ò××éÍø£ºÖ»ÐèҪһ̨ÄÜÉÏÍøµÄPC»òÕßÊÖ»ú£¬£¬£¬£¬£¬ £¬£¬£¬¼´¿ÉÍê³É°²ÅÅ£¬£¬£¬£¬£¬ £¬£¬£¬¼´²å¼´Óᣠ¡£¡£¡£¡£¡£Ö§³Ö»ùÓÚÍø¹ØµÄÍøÂçÍØÆË×Ô¶¯·¢Ã÷£¬£¬£¬£¬£¬ £¬£¬£¬²¢ÒÔͼÐλ¯ÐÎʽ·ºÆð

Ò×ÔËά£ºÔËά¼òÆÓ£¬£¬£¬£¬£¬ £¬£¬£¬ÍøÂçËæÊ±¿É¹Ü£¬£¬£¬£¬£¬ £¬£¬£¬ÈËÔÚÄÇÀïÍøÂç¾ÍÔÚÄÇÀ£¬£¬£¬£¬ £¬£¬£¬ÓÐÏßÎÞÏßÍø¹Ø¾¡ÔÚÕÆÎÕÖС£ ¡£¡£¡£¡£¡£Ö§³ÖÉèÖÃÏ·¢¡¢ÉèÖñ¸·Ý¡¢ÉèÖûָ´¡¢ÏÂÁîµ÷ÊÔ¡¢»á¼ûeWeb¡¢»á¼ûTelnet¡¢»á¼ûSSH¡¢ÖØÆô¡¢×°±¸Éý¼¶

Ò×¼à¿Ø£º¿ÉËæÊ±Éó²éÍøÂ翵½¡¶È£¬£¬£¬£¬£¬ £¬£¬£¬×°±¸ÏêÇé(ϵͳ״̬¡¢Á÷Á¿×ßÊÆ¡¢Á¬Í¨ÐÔ¡¢¹©µç״̬µÈ)£¬£¬£¬£¬£¬ £¬£¬£¬¹ÊÕÏ¿ÉÊÓ£¬£¬£¬£¬£¬ £¬£¬£¬Óû§ÍøÂçÌåÑé¿ÉÊÓ£¬£¬£¬£¬£¬ £¬£¬£¬ÓÐ¸æ¾¯ÊµÊ±ÍÆËÍ£¬£¬£¬£¬£¬ £¬£¬£¬ÓÐÈÕÖ¾ÊÂÎñ¹©»ØËÝ¡£ ¡£¡£¡£¡£¡£Ö§³Ö¸æ¾¯¿Éͨ¹ý΢ÐŹ«Öںš¢Óʼþ¡¢Î¢ÐÅ¡¢ÆóÒµ¶¤¶¤·¢ËÍÌáÐÑ

Ò×ÈÏÖ¤£ºÒÀÍÐÔÆ¶Ë£¬£¬£¬£¬£¬ £¬£¬£¬ÕûÍø±ãÄÜÌṩÉÏÍøÊµÃûÈÏÖ¤£¬£¬£¬£¬£¬ £¬£¬£¬²»±ØÈκεĸ½¼ÓÈí¼þºÍ·þÎñÆ÷¡£ ¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÖ§³ÖSNMP¡¢RMON¡¢SyslogµÈÌØÕ÷À´¾ÙÐÐÍøÂçµÄÒ»Ñùƽ³£Õï¶Ï¼°Î¬»¤£¬£¬£¬£¬£¬ £¬£¬£¬Í¬Ê±¹ÜÀíÔ±¿É½ÓÄÉCLI(ÏÂÁîÐнӿÚ)¡¢WebÍø¹Ü¡¢TelnetµÈ¶àÑù»¯µÄ¹ÜÀíºÍά»¤·½·¨¸üÀû±ã×°±¸µÄ¹ÜÀí¡£ ¡£¡£¡£¡£¡£?

Ö§³ÖSDN¿ØÖÆÆ÷ͳһÄɹÜ£¬£¬£¬£¬£¬ £¬£¬£¬¼ò»¯ÍøÂç¹ÜÀí£¬£¬£¬£¬£¬ £¬£¬£¬½µµÍÍøÂçά»¤±¾Ç®¡£ ¡£¡£¡£¡£¡£

PoEʹÓÃ״̬һĿÁËÈ»£ºÃæ°å×Ô´øÒ»¼üÉó²éPoE¹©µç״̬¹¦Ð§µÄPoE°´Å¥£¬£¬£¬£¬£¬ £¬£¬£¬Çá°´¼´¿ÉÉó²é×°±¸Ä¿½ñµÄͨѶ״̬ºÍ¹©µç״̬£¬£¬£¬£¬£¬ £¬£¬£¬ÈÃÄú¶ÔËùÓж˿ÚPoE¹©µçµÄ״̬ÁËÈ»ÓÚÐÄ¡£ ¡£¡£¡£¡£¡£

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

ϵͳ¹æ¸ñ

ϵͳ¹æ¸ñ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
½»Á÷ÈÝÁ¿ 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 171Mpps 207Mpps 171Mpps 171Mpps 171Mpps
PoE¹©µç±ê×¼ ²»Ö§³Ö Ö§³ÖPoE/PoE+

½Ó¿ÚÓëÄ£¿ £¿£¿£¿£¿£¿£¿é

½Ó¿ÚÓëÄ£¿ £¿£¿£¿£¿£¿£¿é RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
¹Ì»¯ÓªÒµ½Ó¿Ú 4¸ö1G SFP½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö1G SFP½Ó¿Ú
24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 48¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú
¹Ì»¯¹ÜÀí½Ó¿Ú 1¸öRJ45 Console½Ó¿Ú
¹Ì»¯µçÔ´ÊýÄ¿ 1
¹Ì»¯µçÉÈÊýÄ¿ 1

µçÔ´Ó빦ºÄ

µçÔ´Ó빦ºÄ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
Õû»ú×î´ó¹¦ºÄ 24W 40W 24W 40W£¨²»´øPoE¸ºÔØ£© 40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£© 460W£¨PoEÂúÔØ£©
¶î¶¨ÊäÈëµçѹ¹æÄ£ 100Vac~240Vac,47~63Hz 100Vac~240Vac,47~63Hz 100Vac~240Vac,47~63Hz 100V AC~240V AC£¬£¬£¬£¬£¬ £¬£¬£¬50~60Hz
127V ~386Vdc 127V ~410Vdc 127V ~386Vdc 192V DC~290V DC
×î´óÊäÈëµçѹ¹æÄ£ 90V AC~264V AC£¬£¬£¬£¬£¬ £¬£¬£¬47~63Hz 90V AC~264V AC£¬£¬£¬£¬£¬ £¬£¬£¬47~63Hz 90V AC~264V AC£¬£¬£¬£¬£¬ £¬£¬£¬47~63Hz 90V AC~264V AC£¬£¬£¬£¬£¬ £¬£¬£¬50~60Hz
¶î¶¨ÊäÈëµçÁ÷ 0.6A 1.5A 0.6A 6.8A 6.8A

³ß´çÓëÖØÁ¿

³ß´çÓëÖØÁ¿ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 440mm x 220mm x 44mm
440mm x 220mm x 44mm
V2.XX°æ±¾£º440mm x 220mm x 43.6mm
ÖØÁ¿ 2.45kg 2.83kg 2.45kg 3.8kg 3.8kg
»ú¼Ü³ß´ç 1RU
×°Ö÷½·¨ ×ÀÃæ/±Ú¹Ò/»ú¼Ü£¨¹ñ£©

ÇéÐÎÓë¿É¿¿ÐÔ

ÇéÐÎÓë¿É¿¿ÐÔ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
ÏßÀÂÈȲå°Î Console¿Ú¡¢ÓªÒµ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö
ÎÂ¶È ÊÂÇéζȣº0°C~50°C
´æ´¢Î¶ȣº-40°C~70°C
º£°Î1800~5000m£ºº£°ÎÿÉý¸ß100m£¬£¬£¬£¬£¬ £¬£¬£¬×î¸ßζȹæ¸ñ½µµÍ0.6¡æ
ʪ¶È ÊÂÇéʪ¶È£º10%RH~90%RH
´æ´¢Êª¶È£º5%RH~95%RH
ÔëÉù £¼45dBA £¼45dBA £¼45dBA £¼78dBA £¼78dBA
É¢ÈÈ ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬ £¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬ £¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬ £¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬ £¬£¬£¬²à½øºó³ö ·çÀäÉ¢ÈÈ£¬£¬£¬£¬£¬ £¬£¬£¬²à½øºó³ö
ÎÂ¶È¼à¿Ø ÎÂ¶È¼à¿Ø£ºÖ§³Ö
ζȸ澯£ºÖ§³Ö
¹ýα£»£»£»£»£»£»¤£ºÖ§³Ö
µçÉÈ¼à¿Ø ²»Éæ¼° ¹ÊÕϸ澯£ºÖ§³Ö
ÊÖ¶¯µ÷ËÙ£º²»Ö§³Ö
ÖÇÄܵ÷ËÙ£ºÖ§³Ö
Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§
µçÔ´¼à¿Ø ²»Éæ¼° Ä£¿ £¿£¿£¿£¿£¿£¿é¼à¿Ø£º²»Ö§³Ö
¹ÊÕϸ澯£ºÖ§³Ö
ÖÇÄÜÉϵ磺²»Ö§³Ö
·ÀÀ× 10kV

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S5000-24GT4SFP/ RG-S5000-24GT4XS RG-S5000-48GT4XS RG-S5000-24GT4SFP-P/ RG-S5000-24GT4XS-P
PoE ²»Ö§³Ö ²»Ö§³Ö ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¼æÈݷDZê×¼PD×°±¸
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
MACµØÖ·±í Ö§³Ö¾²Ì¬MACµØÖ·
Ö§³ÖMACµØÖ·¹ýÂË
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö»ù±¾QinQ
Ö§³ÖÎÞаQinQ
¶þ²ã»·ÍøÊÖÒÕ Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS£¬£¬£¬£¬£¬ £¬£¬£¬Çл»Ê±¼ä≤200ms£¬£¬£¬£¬£¬ £¬£¬£¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·¼æÈÝ
¶Ë¿Ú¾ÛºÏ Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨
Ö§³ÖLACP¶¯Ì¬¾ÛºÏ
Ö§³ÖLACPÓÅÏȼ¶/ЭÉÌ·½·¨ /×î´ó¿É¾ÛºÏ¿ÚÊýÄ¿ÉèÖÃ
Ö§³Ö¿çVSU AP
Mirror Ö§³ÖͨË×ÓªÒµ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú
Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄÍâµØºÍÔ¶³Ì¾µÏñ
Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ
Ö§³ÖRSPANºÍERSPAN
Ö§³Ö¿ç×°±¸µÄÁ÷Á¿¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
VSUÌØÕ÷ Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ
IP·ÓÉ IPv4/IPv6¾²Ì¬Â·ÓÉ¡¢Ö§³ÖRIP¡¢RIPng¡¢OSPF¡¢OSPFv3ЭÒé
ACL Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©
IP·ÓÉ Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
ACL
QoS
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³ÖACL80
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACLÖØ¶¨Ïò
Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
QoS
Çå¾²ÌØÕ÷
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí
¹ýÂ˲»·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»£»£»£»£»£»¤
Çå¾²ÌØÕ÷
EEE
¹ÜÀíÌØÕ÷
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»£»£»£»£»£»¤
Ö§³ÖIEEE 802.3az±ê×¼µÄEEE£¨Energy Efficient Ethernet£¬£¬£¬£¬£¬ £¬£¬£¬½ÚÄÜÒÔÌ«Íø£©ÊÖÒÕ
SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢WIS¹«ÓÐÔÆÆ½Ì¨¹ÜÀí
Õö¿ªÏêϸ²ÎÊý

³£¼ûÎÊÌâ

ÔÝÎÞÎÊÌ⣬£¬£¬£¬£¬ £¬£¬£¬ÎÒÒªÌáÎÊ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿ £¿£¿£¿£¿£¿£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿ £¿£¿£¿£¿£¿£¿
Á¬Ã¦×Éѯ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾ ÎĵµAIÖúÊÖ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿ £¿£¿£¿£¿£¿£¿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿ £¿£¿£¿£¿£¿£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£ ¡£¡£¡£¡£¡£©£¿ £¿£¿£¿£¿£¿£¿
Äú¶ÔÎĵµÊÇ·ñÉÐÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿 £¿£¿£¿£¿£¿£¿
Ϊ¾¡¿ì½â¾öÎÊÌ⣬£¬£¬£¬£¬ £¬£¬£¬ÇëÄúÁôÏÂÁªÏµ·½·¨Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´Ïì£ ¡£¡£¡£¡£¡£¡
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼